Aeonmed Respiratory Ventilator VG70
PRODUCT DESCRIPTION
The VG70 is a comprehensive transportable ICU ventilator including lung protective ventilation modes such as BIVENT and PRVC.
The VG70 has flexible configuration allowing for trolley, bed or ceiling pendant mount. As a cost effective solution the VG70 has a metal based autoclavable exhalation valve with a nonconsumable design built in flow sensor and its ventilation software is upgradeable with the available USB port.
The VG70's optimal ventilator synchrony leads to greater patient comfort, the Leak compensation system precisely controls the tidal volume of each breath delivered to the patient by adjusting compensation dosage automatically.
The VG70 is an optimal combination of invasive and non-invasive ventilator. As noninvasive ventilation is used increasingly in a wide range of clinical situations, we offer a dual solution. The VG70 combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU.
Key Features:
-
12‑Inch High‑Resolution Display: Large touchscreen for clear, real‑time monitoring of patient parameters.
-
Dual Ventilation Modes: Supports invasive (via endotracheal tube or tracheostomy) and non‑invasive (via face mask) ventilation.
-
Comprehensive Ventilation Support: Includes volume‑controlled, pressure‑controlled, and SIMV modes to tailor therapy.
-
Advanced Patient Monitoring: Real‑time waveforms, alarms, and detailed graphs for respiratory parameters.
-
Non‑Invasive Ventilation (NIV): Easily switch to NIV mode to reduce need for invasive procedures.
-
Compact and Easy to Use: Intuitive interface for quick parameter adjustments.
-
Built‑in Alarms: Alerts for parameter abnormalities or operational issues.
-
User‑Friendly Interface: Simplified touchscreen navigation.
-
Portability: Designed to be mobile for easy transport within the hospital
TECHNICAL SPECIFICATIONS
- VCV(A/C) PCV(A/C) PRVC SIMV(VCV)+PSV
- SIMV(PCV)+PSV SIMV(PRVC)+PSV SPONT/CPAP+PSV
- BIVENT+PSV NIV/CPAP NIV-T NIV-S/T
- Apnea Ventilation Smart Suction Manual Breath
- Insp/ Exp Hold ETCO2 Measurement
- Nebulization Wave form Freeze
TECHNICAL FEATURES
| Screen: | 12〞TFT color touch screen (detachable) |
| Supply Gas | O2, 0.28~0.6 MPa |
| Power Supply | AC100~240 V, 50 Hz/60 Hz |
| Communication Interface | RS-232 Port, Nurse call Port, Ethernet Port |
| Dimension (WxDxH) |
322 mm x 375 mm x 366 mm (Main Unit) 547 mm x 675 mm x 950 mm (Cart) |
| Weight |
12.5 kg (Main Unit) 25 kg (Cart) |
| Type | Electronics |
| Configuration |
on casters |
| Tidal Volume: |
20~2000 ml |
| Respiration Rate: |
1~80 bpm |
| Tinsp: |
0.2~9 s |
| Tslope: |
0~2 s |
| Tpause: |
0~4 s |
| I:E Ratio: |
1:10~4:1 |
| FiO2: |
21%~100% |
| Trigger Sensitivity: |
Pressure (-20~0 cmH2O, above PEEP) Flow (0.5~20 LPM) |
| PEEP: |
0~35 cmH2O |
| Psupport: |
0~70 cmH2O |
| Pinsp: |
5~70 cmH2O |
Monitoring
| Pressure Value: |
Ppeak, Pplat, Pmean, Pmin, PEEP |
| Volume / Flow Value: |
Vti, Vte, MV, MVspont |
| Time Value: |
ftotal,fspont, I:E |
| Real Time Curves: |
Pressure-Time, Flow-Time, Volume-Time wave forms Pressure-Volume, Volume-Flow, Flow-Pressure loops |
| Gas Monitoring: |
FiO2, ETCO2 |
| Calculated Values: |
Compliance(C) Resistance(R) MVleak RSBI WOB PEEPi |
| Alarm |
Paw high / low MVe high / low Circuit disconnnect FiO2 high / low Inspiration / Expiratory tidal volume low High Respiration Rate Apnea AC Failure Nebulizer On Low Battery Air /O2 supply down High / Low PEEP Leakage out of range Occlusion |
Stable Condition Phase
-
PRVC and BIVENT employ lung-protective strategies, delivering intelligent ventilation
-
Comprehensive lung mechanics monitoring include compliance, airway resistance, PEEPi and time constant
-
Three waveforms & three loops with user-friendly display provide a continuous monitoring of the patient’s condition
Weaning Phase
-
Various ventilation modes enhance the weaning process
-
The unique trigger and leakage compensation system safeguard each and every patient breath resulting in smooth and comfortable breathing, avoiding extra workload on the patient and promoting recovery
-
RSBI and WOB provide accurate reference for weaning
Rehab Phase
-
Data export port provides connection to hospital monitors and Patient Data
Management Systems
-
Provides pressure support for the patient when spontaneous breathing is present
-
Upgradeable ventilation system software, with an available USB port
Contents in the Box
-
1 × Aeonmed VG70 ICU Ventilator
-
1 × User Manual
-
1 × Power Cable
-
1 × Patient Circuit (for invasive and non‑invasive use)
-
1 × Battery Pack
-
1 × Warranty Card
Warranty: 1.5 Years
Country of Origin- China
Usage instructions
-
Power On: Connect the ventilator to an appropriate power source.
-
Set Ventilation Mode: Choose between invasive or non‑invasive ventilation based on the patient’s condition.
-
Adjust Parameters: Set the desired tidal volume, respiratory rate, PEEP, and other parameters according to patient requirements.
-
Connect the Patient: Attach the appropriate interface (endotracheal tube or mask) based on the selected ventilation mode.
-
Monitor the Patient: Observe real‑time data on the screen and adjust settings as needed.
-
Alarms: Pay attention to alarm notifications for any deviations from set parameters.