Cardiaco II SpO2 Patient Monitoring System
SKU ID:- Save Rs. 24,000
-
FAST SHIPPING
All of our orders are shipped from our warehouse in Bangalore,to the shipping address provided by the customer via our courier partners .
Products will be delivered in 3-5 business days from the day of dispatch.
You will get shipping and delivery updates by text or email.
Occasional delays may occur due to bad weather,festivals and holidays
Delivery in 3-5 business days
-
COD
Cash On Delivery is available all over India excluding some postal codes.
COD eligibility can be checked during checkout process.
Available all over India
-
EMI
EMI options are available
-
RETURN POLICY
Return
Our policy lasts 5 days. If 5 days have gone by since your purchase, unfortunately we can’t offer you a refund or exchange.
To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.
Refunds (if applicable)
Once your return is received and inspected, we will send you an email to notify you that we have received your returned item.
We will also notify you of the approval or rejection of your refund.
If you are approved, then your refund will be processed, and a credit will automatically be applied to your credit card or original method of payment, within a certain amount of days.
5 days return policy
-
FREE SHIPPING
Over purchase of Rs.5000
-
PRODUCTS
100% authentic products
Bedside SpO2 Patient Monitoring System
Model : Cardiaco II Neonatal Specialized Blood Oxygen Monitor Suitable For Neonatal Intensive Care Units
Anti-motion Interference Accurate Detection Under Low Perfusion Display Respiration Rate Support TEMP,NIBP, CO2 (Optional)
Category: BAMC Medical Group
SpO2 measurement range | 1%~100% Ultra wide range |
SpO2 measurement Accuracy | ±2%(70%~100%) |
PR measurement range | 25~250bpm Ultra wide range |
PR measurement Accuracy | The greater of ±2bpm and±2% |
PI display range | 0.02%-20% |
Anti-motion performance
(1~4Hz, 1~2cm fixed/random frequency disturb) |
SpO2±3%
PR ±4bpm |
Low perfusion performance | SPO2 ±2%, PR ±2bpm |
Supporting low perfusion measurement | Can be as low as 0.025% with Original BAMC accessories |
Waveform output | Bar diagram\Pulse wave |
Probe off detection\Probe failure detection | YES |
Alarm management | YES |
Power supply | Type-C, 5V DC |
Breathing measurement(RR) | Optional |
NIBP\Temperature\CO2 | Optional |
l Neonatal Specialized Blood Oxygen Monitor
l Suitable For Neonatal Intensive Care Units
l Anti-motion Interference
l Accurate Detection Under Low Perfusion
l Display Respiration Rate
l Support TEMP, NIBP, CO2 (Optional)