ChoiceMMed Vital Signs Monitor MD2000C

Rs. 57,120.00 Rs. 56,000.00
1%
People are viewing this right now
Vendor: ChoiceMMed
SKU: TTHE297
Availability: In Stock Pre order Out of stock
Categories: Hospital Equipment
sold in last hours

HURRY! ONLY LEFT IN STOCK.

Icon 1
FAST SHIPPING
Delivery in 3-5 business days
Icon 2
COD
Available all over India
Icon 3
EMI
EMI options are available
Icon 4
RETURN POLICY
5 days return policy
Icon 5
FREE SHIPPING
Over purchase of Rs.5000
Icon 6
PRODUCTS
100% authentic products
  • Description
  • Reviews ⭐
Description

Product Description 

Application Range

Adult and pediatric

SpO₂

Measurement range: 70%-100%

Pulse Rate

Measurement range: 30-250bpm

PI*

Measurement range: 0.2%-20%

NIBP

Method: Oscillometric
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/kPa selectable
Measurement Types:Systolic, diastolic, and mean
Over-pressure protection:Yes
Resolution: 1mmHg

Data Transmission

USB or wired LAN or wireless LAN

Alarm

Alarm: NIBP, SpO₂, PR, probe off, finger out, Low voltage
Modes:Visible & 3-level audible alarms, Error code

Storage

Spot-check mode: 200 records
Continuous mode: 72 hours

Display

Type:7” color screenParameters:NIBP, SpO₂, PI*, PR, pulse barwaveform

Appearance

Dimension:292x168x148±5mm
Weight:1.0±0.05kg

Parameters

NIBP(SYS, DIA, MAP) ,SpO₂, PI, PR, pulse bar, waveform

Classification

Protection Class:
Type BF defibrillation proof
Protection against moisture:IPX1
Safety:IEC 60601-1

 

Instructions For Use

  • Open the battery compartment cover, install the No. 7 battery according to the positive and negative signs in the battery compartment, and close the battery compartment cover
  • Pinch the clip, insert the finger under test into the rubber hole, release the finger, and press the key on the panel.
  • Try not to shake or move during use, after the result is displayed, read the data on the screen

Precautions

  1. When using the product for measurement, keep your body as still as possible
  2. During blood oxygen measurement, the same arm should not be tested for blood pressure at the same time; when the peripheral circulation of the subject is severely poor, it will lead to a decrease in arterial blood flow at the measured site, making the measurement inaccurate or impossible measuring
  3. When using the product for measurement, avoid strong light shining on the measuring probe; when the outside has strong light shining on the probe, the operation of the photoelectric receiving device may deviate from the normal value range, resulting in inaccurate measurement, so strong light irradiation should be avoided
  4. For patients with severe anemia, the oximeter measurement does not have clinical significance, that is, if the user is a patient with severe anemia and there is anemia hypoxia, the measured blood oxygen value may be displayed as normal