Contec ECG Machine 12 Channel 1200G
Product Description
The CMS 1200G ECG Machine is an advanced twelve-channel electrocardiograph that simultaneously gathers 12-lead ECG signals and prints the waveforms using a high-resolution thermal printing system. This device is ideal for use in surgery centers, hospitals, clinics, and educational settings. Its versatile design allows it to operate in both AUTO and Manual modes, facilitating efficient recording and displaying of ECG waveforms. The machine's capability to automatically measure and diagnose ECG waveform parameters enhances diagnostic accuracy and reduces the workload for medical professionals.
The CMS 1200G ECG Machine is extensively used by healthcare professionals for diagnosing and monitoring cardiac conditions. It is an invaluable tool in surgery centers, hospitals, and clinics for accurate and reliable ECG readings. Medical students and nurses also utilize this device for training and educational purposes, making it a versatile asset in medical settings.
Key Features
- Recording and displaying ECG waveform in AUTO/Manual mode measuring and diagnosing ECG waveform parameters automatically prompting for “Leadoff” and “Lack of paper
- Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
- Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
- Multiple printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
- Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
- With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor's burden.
- Built-in memory stores up to 1000 cases, convenient for case review and statistic.
- Multi-language (French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
- In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform (commonly, it is 3s case).
Technical Specification
| Screen size | 8 inches |
| Leads | 12 leads |
| Input way | Floating and defibrillation protection |
| Lead | Standard 12 leads(model:BIP0057) |
| Patient leak current | <10µA |
| Input impedance | ≥50MΩ |
| Frequency response | 0.05Hz~150Hz(-3dB) |
| Time constant | Time constant>3.2s |
| CMRR | >60dB, >100dB( Adding filter) |
| EMG interference filter | 35Hz(-3dB) |
| Recording way | Thermal printing system |
| Specification of recording paper | 210mm(W)*20m(L) high-speed thermal paper |
| Paper speed | Auto record: 25mm/s, 50mm/s, error:±5% |
| Rhythm record: 25mm/s, 50mm/s, error:±5% | |
| Manual record:5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, error:±5% | |
| Sensitivity selections | 2.5,5,10,20,40mm/mV, error:±5%. Standard sensitivity is 10mm/mV±0.2mm/mV. |
| Auto record | Record setup according to auto-record format and mode, automatically changing leads, measuring and analyzing. |
| Rhythm record | Record setup according to rhythm record format and mode, automatically measuring and analyzing. |
| Manual record | Record setup according to manual record format, manually changing leads. |
| Measurement parameters | HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P A*is, QRS A*is, T A*is, R(V5) , S(V1) , R(V5)+S(V1) |
| Product safety type | Class I CF applied part; there is defibrillation and pacing protection circuit in it. |
| Enduring polarization voltage | ±300mV |
| Noise level | ≤15µVp-p |
| Fuse specification | 2 pcs φ5*20mm AC time lag; T1.6A/250V(Power supply 220V) |
| Size | 340mm(L)*320mm(W)*85mm(H) |
| Net Weight | 3.2Kg |
Contents in the Box
Standard:
- A lead cable
- A limb electrode
- A chest electrode
- A thermal recording paper
- A power cord
- An earth wire
- A user manual
Optional:
- ECG-Sync software + USB cable
- ECG electrode
- Conductive paste
- USB cable
- Remote Operation Guide
Warranty - 1 Year